TRACECO-T Self-Regulating Heating Cable 10 W/m | Frost Protection for Pipelines (-25°C to +65°C) | Grounding Braid + Outer Sheath
TRACECO-T Self-Regulating Heating Cable 10 W/m | Frost Protection for Pipelines (-25°C to +65°C) | Grounding Braid + Outer Sheath
6.69 €
  1. Heating and self-regulating cables
  1. Heating cables and heat-resistant wires
  2. Heating and self-regulating cables

TRACECO-T Self-Regulating Heating Cable 10 W/m | Frost Protection for Pipelines (-25°C to +65°C) | Grounding Braid + Outer Sheath

Article No.: 
F8-T-10W-BO
TRACECO-T Self-Regulating Heating Cable 10 W/m | Frost Protection for Pipelines (-25°C to +65°C) | Grounding Braid + Outer Sheath
Available for order
6.69 €
Unit price: 6.6929 €/m1
Availability:
External storage
Delivery time:
Inquire
Minimum order quantity:
500 m
Wattage :
10 W
20 W
30 W
40 W

Short Description: 

The TRACECO-T heating cable is a self-regulating heating cable primarily designed for frost protection of pipelines. Thanks to its self-regulating technology, the cable's power adjusts according to the surrounding temperature, preventing overheating and improving energy efficiency.

  • Details
  • Info
  • Opinions
  • User guide
Details

Detailed Description: 

The self-regulating technology allows the cable's performance to automatically change with variations in ambient temperature: the heating power increases in cold conditions and decreases in warmer temperatures, ensuring efficient and safe operation.
The parallel construction allows the cable to be cut to the required length on-site, making it customizable for the specific application.
It is widely used in various industrial and residential heating applications:

  • Frost protection for potable water, wastewater, and industrial pipelines
  • Heat maintenance for liquids transported in industrial and agricultural facilities (e.g., chemicals, oils)
  • Ice prevention for gutters and drains
  • Heat maintenance for large storage tanks in industrial plants
  • Keeping fuel and chemical tanks warm to reduce viscosity
  • Protection for garden taps, water meters, and smaller pipelines during cold months
  • Protection for pipes of solar collectors and heat pumps

Technical Specifications:

  •  Construction: Grounding Braid + Outer Sheath
  • Insulation: Black thermoplastic outer sheath
  • Voltage: 230 V
  • Power: 10 W/m 
  • Maximum Operating Temperature (on): 65°C 
  • Maximum Operating Temperature (off): 80°C 
  • Minimum Installation Temperature: -25°C
  • Bend Radius: Minimum 25 mm

Operation:

The TRACECO-T heating cable is an easy-to-install and energy-efficient solution for pipe freeze protection. Thanks to its self-regulating technology, it does not require constant supervision and can be safely used in both indoor and outdoor applications.

Info
Voltage:
230 V
Wattage:
10 W
Type of insulation:
Grounding Braid + Outer Sheath
Operating temperature:
-25°C to +65°C
Weight:
16 kg/m
Minimum order quantity:
500 m
Quantity options:
500 m, 1000 m, 1500 m, 2000 m, ...
Opinions
Be the first to review this product!
Review
User guide

Installation Instructions


The heating cable must be placed on the lower part of the pipeline. It is important not to use the cable on pipes that can reach temperatures of up to 65°C. This cable is only suitable for frost protection of metal or plastic pipes. For plastic pipes, it is recommended to first apply an aluminum adhesive tape to the pipe to ensure better heat conduction.

How to select the appropriate cable?

  • The selected cable heating length must match the length of the pipe.
  • The pipe surface should be clean and dry before securing the cable.
  • The cable should be secured with PVC or aluminum adhesive tape. The ELAA-50  type aluminum tape is particularly recommended as it helps distribute heat evenly on plastic pipes.

Thermostat Installation

The thermostat (with black casing) should be attached directly to the pipe.

Insulation and Safety

  • The system should be covered with an insulation layer to reduce heat loss and save energy.
  • Recommended insulation thickness: minimum 13-19 mm.
  • Ensure that the grounding is properly connected, as this guarantees safe operation. 

The connector cable contains three wires: phase, neutral, and ground. Make sure that the system is correctly connected to the ground to avoid electrical issues.

Customer account
  • Login
  • Registration
  • Profile
  • Basket
  • Favorites
Information
  • General terms and conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact Us
Szinimpex Kft.
  • Garay u. 8., Kecskemét, 6000
  • +36306272127
  • marketing@szinimpex.hu
  • facebook

  • instagram

Opening Hours

Monday: 8:00 – 16:00
Tuesday: 8:00 – 17:00
Wednesday: 8:00 – 17:00
Thursday: 8:00 – 16:00
Friday: 8:00 – 14:00
Sat./Sun.: Zárva

Pénzügyileg stabil vállalkozás a Dun & Bradstreet minősítése alapján
AFR 2.0 alapú azonnali átutalási megoldások a SimplePay termékekben
simplepay_hu_v2
  • Kifutó termék!
  • Heating Elements, Heating Rods
  • Heating cables and heat-resistant wires
  • Heaters, heating panels
  • IBC tank and drum heaters
  • Industrial heating systems
  • Accessories
Change language
  • hu
  • en
  • rs
  • hr
Change currency
Login
Register
Cookie settings
Our website uses cookies that are essential for basic operation. You can enable marketing related cookies for broader functionality. In this case you also accept the privacy policy
Cookies required for operation are essential for the basic functions of the website, and the website will not function properly without them. These cookies do not store personally identifiable information.
Marketing cookies are used to track visitors’ activity on the website. The goal is to display relevant ads to individual users (e.g., Google Ads, Facebook Ads) and encourage engagement, which makes our website more valuable.
Statistical cookies help website owners understand how visitors interact with the site by collecting and reporting information anonymously.
Personalization cookies allow us to remember information that changes the behavior or appearance of the website.