We kindly inform our customers that our base currency has changed from Hungarian Forint to Euro. Our prices vary according to the daily exchange rate. Thank you for your understanding!

Szinimpex fűtőszálak

Have question? +36306272127

Categories
Szinimpex fűtőszálak

Have question? +36306272127

  • Categories
    • Kifutó termék!
    • Heating Elements, Heating Rods
    • Heating cables and heat-resistant wires
    • Heaters, heating panels
    • IBC tank and drum heaters
    • Industrial heating systems
    • Accessories
    • Household use
    • Professional Application
TRACECO-R Self-Regulating Heating Cable 40W/m | Frost Protection for Cold Room Doors (-20°C to +65°C) | Polyolefin Insulation
TRACECO-R Self-Regulating Heating Cable 40W/m | Frost Protection for Cold Room Doors (-20°C to +65°C) | Polyolefin Insulation
6.63 €
  1. Heating and self-regulating cables
  1. Heating cables and heat-resistant wires
  2. Heating and self-regulating cables

TRACECO-R Self-Regulating Heating Cable 40W/m | Frost Protection for Cold Room Doors (-20°C to +65°C) | Polyolefin Insulation

Item number: 
F8-R-40W
TRACECO-R Self-Regulating Heating Cable 40W/m | Frost Protection for Cold Room Doors (-20°C to +65°C) | Polyolefin Insulation
In stock
6.63 €
Unit price: 6.6294 €/m1
Availability:
External storage
Delivery time:
1-3 nap
Wattage Wattage :
30 W
40 W

Short Description:

The TRACECO-R self-regulating cable is designed to prevent freezing of cold room doors, thresholds, and floors, as well as for heating condensate drainage pipes.

We also recommend the following product as an accessory
  • Details
  • Data
  • Reviews
  • User guide
Details

Short Description:

The TRACECO-R self-regulating cable is designed to prevent freezing of cold room doors, thresholds, and floors, as well as for heating condensate drainage pipes.

Detailed Description:

Heating cables prevent door icing, ensuring easy opening and closing while helping to maintain efficient cooling or freezing processes. Thanks to its self-regulating technology, the TRACECO-R heating cable automatically adjusts its power output based on ambient temperature changes. Its parallel construction allows it to be cut to the desired length without requiring predefined sections. This simplifies installation and provides a time- and cost-effective solution.

Technical Specifications:

  • Construction: Polyolefin insulation
  • Voltage: 230 V
  • Power Output: 40 W/m at 10°C
  • Maximum Operating Temperature (on): 65°C
  • Maximum Operating Temperature (off): 80°C
  • Minimum Installation Temperature: -20°C
  • Minimum Bending Radius: 25 mm

Usage Instructions:

1. Selecting and Cutting the Cable

2. Mounting on the Surface:

  • For Pipelines: The cable is secured in parallel or spiral form along the pipe using special mounting tapes or cable ties.
  • For Surfaces and Floors: The cable should be attached to the surface using appropriate fasteners or rail systems.

3. Electrical Connection: The cable is connected to the power supply through a junction box. Thanks to its self-regulating technology, no separate thermostat is required, but a temperature control device can be used for energy efficiency and regulation.

4. Insulation and Protection: To enhance efficiency, the heated surface (e.g., pipelines) should be covered with thermal insulation.

5. Commissioning and Inspection: After installation, the system should undergo an electrical inspection, followed by a trial run of the heating cable to ensure proper operation.

Data
Voltage:
230 V
Wattage:
40 W
Type of insulation:
Polyolefin Inner Insulation + Outer Jacket
Operating temperature:
-20°C to +65°C
Weight:
60 g/pcs
Reviews
Be the first to write a review!
Write a review
User guide

Installation Instructions

The heating cable must be placed on the lower part of the pipeline. It is important not to use the cable on pipes that can reach temperatures of up to 65°C. This cable is only suitable for frost protection of metal or plastic pipes. For plastic pipes, it is recommended to first apply an aluminum adhesive tape to the pipe to ensure better heat conduction.

How to select the appropriate cable?

  • The selected cable heating length must match the length of the pipe.
  • The pipe surface should be clean and dry before securing the cable.
  • The cable should be secured with PVC or aluminum adhesive tape. The ELAA-50  type aluminum tape is particularly recommended as it helps distribute heat evenly on plastic pipes.

Thermostat Installation

The thermostat (with black casing) should be attached directly to the pipe.

Insulation and Safety

  • The system should be covered with an insulation layer to reduce heat loss and save energy.
  • Recommended insulation thickness: minimum 13-19 mm.
  • Ensure that the grounding is properly connected, as this guarantees safe operation. 

The connector cable contains three wires: phase, neutral, and ground. Make sure that the system is correctly connected to the ground to avoid electrical issues.

Customer account
  • Sign In
  • Sign Up
  • My Profile
  • Cart
  • My Favorites
Information
  • Terms and Conditions
  • Privacy Policy
  • Payment
  • Shipping
  • Contact details
Szinimpex Kft.
  • Garay u. 8., Kecskemét, 6000
  • +36306272127
  • marketing@szinimpex.hu
  • facebook

  • instagram

Opening Hours

Monday: 8:00 – 16:00
Tuesday: 8:00 – 17:00
Wednesday: 8:00 – 17:00
Thursday: 8:00 – 16:00
Friday: 8:00 – 14:00
Sat./Sun.: Zárva

Pénzügyileg stabil vállalkozás a Dun & Bradstreet minősítése alapján
AFR 2.0 alapú azonnali átutalási megoldások a SimplePay termékekben
simplepay_hu_v2
stripe_com
  • Kifutó termék!
  • Heating Elements, Heating Rods
  • Heating cables and heat-resistant wires
  • Heaters, heating panels
  • IBC tank and drum heaters
  • Industrial heating systems
  • Accessories
  • Household use
  • Professional Application
Change language
  • hu
  • en
  • rs
  • hr
Change currency
Sign in
Sign Up
Privacy settings
Our website uses cookies necessary for basic functionality. You can allow additional cookies for broader features (marketing, analytics, personalization). For more details, see our Privacy Policy in the Privacy Notice.
Cookies required for operation are essential for the basic functions of the website, and the website will not function properly without them. These cookies do not store personally identifiable information.
Marketing cookies are used to track visitors’ activity on the website. The goal is to display relevant ads to individual users (e.g., Google Ads, Facebook Ads) and encourage engagement, which makes our website more valuable.
Statistical cookies help website owners understand how visitors interact with the site by collecting and reporting information anonymously.
Personalization cookies allow us to remember information that changes the behavior or appearance of the website.